Hinged Single-Leaf
The standard exterior door. Welded or double-skin panel with dogged closure for weathertight or watertight service.
Custom aluminium and stainless marine doors — hinged, sliding, French, Dutch, companionway, joiner, power and radius. Built to your opening in Hialeah. A-class fire-rated assemblies supplied from certified manufacturers.
Resists incidental spray and wash-down. Not a barrier against sustained wave pressure.
Built to resist driving rain, wind, spray and light wave pressure. The common specification for exposed openings above the freeboard deck.
Designed to hold static head from either side and prevent flooding between compartments. Specified where subdivision integrity matters.
Sealed against vapour migration as well as water, for spaces where atmosphere separation is specified.
Tell us the deck, the compartment either side and whether the opening is above or below the freeboard deck. +1 (332) 208-4278
The standard exterior door. Welded or double-skin panel with dogged closure for weathertight or watertight service.
Horizontal sliders with drained sills, for wheelhouse ventilation and side-deck access.
Paired leaves with astragal or mullion, for wide openings where a single panel would be unwieldy.
Operates as a single panel for normal access, with an independently opening upper leaf for ventilation and sightlines.
Access doors at raised sills for below-deck entry, sized around the sill height your structure already has.
Lightweight aluminium honeycomb-core doors for accommodation and interior spaces, including government refit packages.
Electrically operated hinged and sliding doors with manual override, for high-traffic and accessibility-driven openings.
True radius-corner and curved doors matched to an existing pattern — the openings most shops decline to quote.
We source A-class rated door assemblies from certified manufacturers and deliver them as part of your package. We do not fabricate rated assemblies in house.
Integrity for 60 minutes with no insulation requirement. Stops flame and smoke passage.
Integrity plus insulation limiting unexposed-face temperature rise for 15 minutes.
Integrity plus 30 minutes of insulated protection on the unexposed face.
Integrity plus 60 minutes of insulation. Required between machinery spaces and accommodation.
Send the boundary, the required rating and whether watertight or weathertight integrity is also specified.
We match the requirement to a manufacturer holding current type approval for that exact assembly and size.
The type-approval certificate is issued by the manufacturer and provided with the unit for your submittal package.
Delivered with your fabricated doors as one package, with installation support available.
Double-skin. Aluminium skins captured in an extruded panel frame over a solid polyurethane insulating core. Lighter, quieter and economical — the standard choice for high-traffic interior and protected exterior openings.
Welded single panel. Fully welded construction giving a smooth, seamless exterior that takes yacht-quality paint. Specified where appearance, strength or watertight rating governs.
Tempered, laminated, insulated, heated, tinted and coated glazing are all available in doors. Full specifications are on the Marine Windows page.
5000-series marine aluminium sheet and plate, 6000-series marine alumunum extrusions, 316 stainless, carbon steel, marine-coated steel
Custom powder-coated colors matched to a supplied color sample, chip or RAL number
Marine-grade epoxy and polyurethane coating systems for steel frames
Brushed, polished, passivated or specified coated finishes for stainless-steel frames
Opening height and width, corner radius, sill height, bulkhead thickness and the existing frame detail.
Upload measurements, photographs and drawings. Photograph the existing frame and dogging in place.
Drawing review within one business day, confirming both dimensional fit and whether a rated assembly is required.
Built in Hialeah, or sourced from a certified partner if the boundary requires a rated assembly. Shipped as one package.
Built to these construction requirements, with class approval available on request. Strengthen only for societies where a current type-approval certificate is held on file.
Weathertight is specified for exposed openings above the freeboard deck, where the door has to resist driving rain, wind, spray and light wave pressure. Watertight is specified where the door forms part of the vessel’s subdivision and has to hold static head from either side in a flooding event, typically below the freeboard deck. If you tell us the deck and the compartments either side, we will specify it with you.
No. We supply A-class rated assemblies from manufacturers who hold current type approval, and we pass their certificate through with the unit. An A-rating belongs to a tested assembly rather than to a material or a shop, so the certificate has to come from whoever tested that exact configuration. We fabricate the aluminium and stainless doors ourselves and supply the rated assemblies alongside them as one package.
An A60 assembly holds fire integrity and limits temperature rise on the unexposed face for sixty minutes under the standard fire test. It is normally required between machinery spaces and accommodation or service spaces. A0, A15 and A30 apply to lower-risk boundaries. Which one you need is set by the boundary on your fire control plan, not by preference — send us the plan and we will match it.
Dogs create the compression that makes the seal work, so the number rises with the tightness rating — a spray-tight door may need two, a weathertight door six, a watertight door twelve. Quick-acting dogging closes all points in a single motion, which matters where a door has to be secured fast or frequently.
Opening height and width, corner radius, sill height, bulkhead or frame thickness, swing direction, and the required tightness rating. For a replacement, photographs of the existing frame and dogging in place are worth more than a written description. DWG, PDF, JPG and PNG all upload fine.
Fabricated doors typically ship in 9 to 12 weeks from drawing approval. Supplied A-class assemblies run to the partner manufacturer’s schedule, which we confirm at quote rather than after the order.
Send measurements, drawings, photographs or a template. We will confirm fit and glazing specification before anything is cut.
Monday to Friday, 7:00–16:00 ET
2637 W 76 ST, HIALEAH, FL 33016